Fri. 09/28
Poster session 2 (P40-P64) / 1.15 - 2.00 pm
Clinical VAD studies and experiment
Chairman 1: B. Walpoth, Genéva, Switzerland (P40-P45) / Chairman 2: C. Klopsch, Rostock, Germany (P46-P50)
01.15 - 02.00 pm | P40 | Comparative analysis of GME activity in 3 circuit designs during pulsatile and non-pulsatile CPB A. Milano, Verona, Italy |
P41 | Does age matter in the venoarterial extracorporeal life supports, which are irrelevant to major operation? T. Kim, Seoul, South-Korea |
|
Evaluation of platelet aggregation in patients supported by centrifugal continuous flow left ventricular assist device K. Suzuki, Tokyo, Japan |
||
P43 | Extracorporeal Membrane Oyxgenation for the Treatment of Acute Respiratory Failure due to Respiratory Syncytial Virus after Congenital Heart Surgery C. Yerebakan, Istanbul, Turkey |
|
P44 | cancelled | |
P45 | Oxygenated shunting from right to left: a minimizes atrio-atrial ECMO for midterm lung assistance A. Goetzenich, Aachen, Germany - presented from J. Spillner |
|
P46 | First steps in muscle perfusion monitoring for biomechanical cardiac assist methods P. R. J. Margaritoff, Hamburg, Germany |
|
P47 | A Transcutaneous Energy Transmission System Delivering up to 45 Watt to an Artificial Heart C. Sommer, Vienna, Austria |
|
P48 | Preliminary study on the development of artificial papillary muscle using shape memory alloy fibre Y. Shiraishi, Sendai, Japan |
|
P49 | Investigation of the initial phase of thrombus generation K. Affeld, Berlin, Germany |
|
P50 | Effect of resistance, compliance and position on the performance of the intra-aortic balloon (IAB): an experimental study G. Bruti, Uxbridge, UK |
|
Poster session 2 (P51-P55) / 1.15 - 2.00 am
Valves
Chairman 1: U. Steinseifer, Aachen, Germany / Chairman 2: P. Donndorf, Rostock, Germany
01.15 - 02.00 am | P51 | Influence of the bulging sinus of the aorta on the flow and leaflet movement of the aortic valve T. Akutsu, Yokohama, Japan |
P52 | Hybrid solution for aortic valves examination M. Darowski, Warsaw, Poland |
|
P53 | Optimal implantation of a mitral mechanical heart valve D. Berca, Tel Aviv, Israel |
|
P54 | Investigation of adjustable parameters for the optimization of polyurethane heart valve kinematics and durability S. Sonntag, Aachen, Germany |
|
P55 | Numerical investigation of the hemodynamics of transcatheter aortic valves Y. Brener, Tel Aviv, Israel |
|
P56 | A new generation of transcatheter heart valves B. Rahmani, London, UK |
Poster session 2 (P56-P64) / 1.15 - 2.00 pm
Modeling and pump control
Chairman 1: B.Meyns, Leuven, Belgium (P56-P59) / Chairman 2: J. Grosshauser, Berlin, Germany (P60-P63)
01.15 - 02.00 pm | P57 | Development of a novel drive mode for preventing aortic insufficiency during continuous-flow LVAD support by electrocardiogram-synchronized rotational speed change K. Kishimoto, Osaka, Japan |
P58 | Cardiovascular Simulator as a tool for remote training application K. Zielinski, Warsaw, Poland |
|
P59 | Influence of arterial compliance on baroreflex activity during IABP assistance: a hybrid model study L. Fresiello, Rome, Italy |
|
P60 | Pump and circulatory parameters interactions during continuous flow pump assistance. Model study G. Ferrari, Rome, Italy |
|
P61 | Aortic and mitral regurgitation changes during parallel or serial LVAD assistance A. DiMolfetta, Rome, Italy |
|
P62 | A numerical model of the coronary circulation to evaluate the fractional flow reserve (FFR) A. DiMolfetta, Rome, Italy |
|
P63 | Left-right flow balance investigation of a total artificial heart M. Laumen, Aachen, Germany |
|
P64 | Safety Control applied to a Ventricular Assist Device A. Cavalheiro, Sao Paulo, Brazil |